Ad Code

Alamat : Jl. H Kelik No.20B Kelapa Dua Kebon Jeruk Jakarta Barat 11550 Telp. 021.220.54159 Up Asep | WA : 0822.1729.4199 e-mail : atantan.margasetia@gmail.com

Fluke 115 Digital Multimeter



  • Toko MARGA SETIA Jual Alat Alat Teknik Sipil, Alat Lab, Alat Ukur dan Alat Survey, GPS, Sirine dan Alat Geologi



    Produk yang ditawarkan :
    Total Station. Waterpass. Theodolite Digital. Hammer test. Anemometer.Anggle Meter.Lux Meter. Sound Level. Kompas. Clinometer. Weather Station. GPS Geodetik. GPS Map. GPS Echosounder. Abney Level. Rain Gauge / Curah Hujan. Sirine. Levelling Laser. Fusion Splicer. Digipas. Laser Meter.Meteran. Waterpass Digital. Coating Thiknes. Thermometer. Thermo hygrometer. SIRINE.Kompas, Clinometer, Abney Level, Flowacth, Laser Range Finde,Fusion Splicer, Sand Cone test, DCP, Palu geologi, Loupe, Batre dan Charger, Tripod, Prisma Polygon, Single Prisma, mini Prisma, Bak Ukur, Range Pole, Kabel Data,DO meter, FLIR, MultiMeter, Clamp Meter, Dll masih banyak lagi pokonya.

    The Intelligently Designed Solution for Field Service Technicians
    With its simple operation, compact design and ease of use, the Fluke 115 True RMS digital multimeter provides the perfect answer for general purpose electrical and electronic test requirements. The Fluke 115 displays True RMS voltage and current readings with 600 count resolution, continuity and capacitance, making it perfect for quick verifications and field service use.
    Fluke 115 Digital Multimeters are independently tested for safe use in CAT III 600V Environments.

    • Large white LED backlight to work in poorly lit areas
    • Resistance and continuity
    • Frequency and capacitance
    • Maximum Voltage ac/dc 600V
    • 10A ac/dc current measurement (20 A overload for 30-seconds max)
    • Min/Max/Average to record signal fluctuations
    • CAT III 600 V safety rated


    Specifications

    Maximum voltage between any terminal and earth ground 600 V
    Surge protection 6 kV peak per IEC 61010–1 600 VCAT III, Pollution Degree 2
    Display Digital: 6,000 counts, updates 4 per second
    Bar graph 33 segments, updates 32 per second
    Operating temperature -10°C to + 50°C
    Storage temperature -40°C to + 60°C
    Battery type 9 volt Alkaline, NEDA 1604A/ IEC 6LR61
    Battery life 400 hours typical, without backlight
    Accuracy Specifications
    DC millivolts Range/resolution 600.0 mV / 0.1 mV
    Accuracy ± ([% of reading] + [counts]): 0.5% + 2
    DC volts Range/resolution 6.000 V / 0.001 V
    60.00 V / 0.01 V
    600.00 V / 0.1 V
    Accuracy ± ([% of reading] + [counts]): 0.5% + 2
    AC millivolts1 True RMS Range/resolution 600.0 mV / 0.1 mV
    Accuracy 1.0% + 3 (DC, 45 Hz to 500 Hz)
    2.0% + 3 (500 Hz to 1 kHz)
    AC volts1 True RMS Range/resolution 6.000 V / 0.001 V
    60.00 V / 0.01 V
    600.0 V / 0.1 V
    Accuracy 1.0% + 3 (DC, 45 Hz to 500 Hz)
    2.0% + 3 (500 Hz to 1 kHz)
    Continuity Range/resolution 600 Ω / 1 Ω
    Accuracy Beeper on < 20 Ω, off > 250 Ω detects opens or shorts of
    500 μs or longer.
    Ohms Range/resolution 600.0 Ω / 0.1 Ω
    6.000 kΩ / 0.001 kΩ
    60.00 kΩ / 0.01 kΩ
    600.0 kΩ / 0.1 kΩ
    6.000 MΩ / 0.001 MΩ
    Accuracy 0.9% + 1
    Range/resolution 40.00 MΩ / 0.01 MΩ
    Accuracy 5% + 2
    Diode test Range/resolution 2.00 V / 0.001 V
    Accuracy 0.9% + 2
    Capacitance Range/resolution 1000 nF / 1 nF
    10.00 μF / 0.01 μF
    100.0 μF / 0.1 μF
    9999 μF / 1 μF
    100 μF to 1000 μF
    Accuracy 1.9% + 2
    Range/resolution > 1000 μF
    Accuracy 5% + 20%
    Lo-Z capacitance Range 1 nF to 500 μF
    Accuracy 10% + 2 typical
    AC amps True RMS
    (45 Hz to 500Hz)
    Range/resolution 6.000 A / 0.001 A
    10.00 A / 0.01 A
    Accuracy 1.5% + 3
    20 A overload for 30-seconds max
    DC amps Range/resolution 6.000 A / 0.001 A
    10.00 A / 0.01 A
    Accuracy 1.0% + 3
    20 A overload for 30-seconds max
    Hz (V or A input)2 Range/resolution 99.99 Hz / 0.01 Hz
    999.9 Hz / 0.01 Hz
    9.999 kHz / 0.001 kHz
    50 kHz / 0.01 kHz
    Accuracy 0.1% + 2
    1. All AC voltage ranges except Auto-V/LoZ are specified from 1% to 100% of range. Auto-V/LoZ is specified from 0.0 V.
    2. Frequency is AC coupled, 5Hz to 30 kHz for AC voltage.
    2. Temperature uncertainty (accuracy) does not include the error of the thermocouple probe.
    2. Frequency is AC coupled, 5 Hz to 50 kHz for AC voltage. Frequency is DC coupled, 45 Hz to 5 kHz for AC current.
    2. Temperature Range/Resolution: -40°F to 752°F / 0.2°F.
    Mechanical & General Specifications
    Size 167 x 84 x 46 mm (6.57 x 3.31 x 1.82 in)
    Weight 550 g



Posting Komentar

1 Komentar

  1. I have been looking for fluke multimeter 115 and Fluke test equipment and was not able to get the same product from their site. I wanted to connect with a well known brand as the quality has always been a top priority. Your blog helped me to reach Omni Controls Inc. which sells apt fluke electrical testers I wanted. I ordered the fluke multimeter 115 which was easy to use and have a compact design which addresses the issues of a variety of field service specialists. Fluke test equipment and Fluke multitester permit electrical and maintenance professionals the capacity to investigate and avoid electrical issues Thank You for your Blog!

    BalasHapus

Untuk Informasi harga dan stok anda bisa langsung hubungi 082217294199 email atantan.margasetia@gmail.com